Manuale d’uso. Codici errore Condizionatore Mitsubishi Electric più frequenti con la risoluzione al problema. For free inverter, i have a problem when i start a split after 3 minutes compressor suddenly power on and off then only fan working in indoor kindly suggest what is tha problem. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. Condensate Overflow Protection. Il futuro ha una nuova dimensione: vivilo con il nuovo Galaxy S20! In dry mode, the indoor fan may stop for up to three minutes during the compressor off delay. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. If indoor unit detects the indoor ambient temperature sensor is open circuit or shortcircuit for 5-secsuccessively, indoor ambient temp. 7 0 obj The wiring terminal between indoor evaporator temperature sensor and controller is loosened or poorly contacted; There’s short circuit due to the trip-over of the parts on controller; Indoor evaporator temperature sensor is damaged. I have gree 12 btu he work properly on heat mode but after h1 defrost I loose the hot air whats the problem? If remote controller needs to be replaced,contact a qualified service professional for assistance. Fujitsu Error and Fault Codes – Airpro can diagnose all Fujitsu Air conditioning fault and error codes. Turn unit off. Sir plz tell me how to fix u1 error gree Invertar 1.5 ton. The unit will not run until evaporator temperature is higher than the protective temp. I get it sometimes but then ac starts working fine after some restarts, My 2.0 ton heat/cool ac went auto of after 5 min and some time on without remote, Error code(Pc) is coming for gree consealed ac what can i do now. A/C Status: Defrosting will occur in heating mode. Chiedi un preventivo e sopralluogo gratuito a Lombardia. The indoor unit is not level right to left. My ac gree inverter duck split.error coming after 30 minutes.what problem.ican fix it.please any body help me? Wiring terminal 4V is loosened or broken; Turn unit off, pull out power plug. Batteries in the remote controller are low. Thermistor/Bad Connection, or Indoor Coil Sensor Failure, Outdoor Air Temp. Switch off the unit or re-energize the unit aftercutting off power to reset this protection. Cause: There are a number of possible reasons. Visualizza e scarica il pdf, trova le risposte alle domande più frequenti e leggi il feedback degli utenti. If it’s no use, please replace control panel AP1. Whats the problem? Please can help me any body for this. Poor heat exchange (including filth blockage of heat exchanger and bad radiating environment ); Ambient temperature is too high. These cookies will be stored in your browser only with your consent. A/C Status: During cooling operation, compressor will stop while indoor fan will operate; during heating, the complete unit will stop operation. Problem: Outdoor tube temperature sensor is open/short-circuited. In heating mode, the indoor fan may not start for three minutes if the room temperature is very low.This is to prevent blowing cold air. Possible Causes: Refer to the malfunction analysis (IPM protection, loss of synchronism protection and overcurrent protection of phase current for compressor. If indoor unit detects the evaporator temperature is lower than protective temperate value after the unit has been running for a period of time undercooling or dry mode, the unit will report this fault, in which case the compressor and outdoor fan motor will be stopped. Cambia la forma del domani con il nuovo Galaxy Z Flip. Motor is not installed properly and tightly. %�쏢 What is it mean? Navigando in internet ci sono varie rtisposte di altri utenti. The unit will restart operation after evaporator temperature is lower than the protective temp. Water leaking from the indoor unit into the room. Overload Protection. ROMA TAXI e NCC. What is J9.. what is the meaning and what is the solution for that.. Error code on air conditioner display is E2, Cassette Ac O. %PDF-1.4 The wiring terminal between outdoor ambient temperature sensor and controller is loosened or poorly contacted; Outdoor ambient temperature sensor is damaged. The wiring of the high pressure switch is loosened. Wait until outside temperature drops to under 95˚F (35˚C). Sul quadro di valutazione dei nuovi condizionatori d'aria appare nei seguenti casi: congelamento dell'evaporatore - si verifica quando la quantità di refrigerante nell'impianto è insufficiente, l'evaporatore e i filtri sono sporchi; If the outdoor unit does not receive data from indoor unit, communication malfunction will be reported. Cause: It is normal for the system to develop condensation or moisture on the discharge air louvers when cooling warm humid air for a long period of time. Solution: If water is leaking into the room, it may indicate one of the following Do not repair the air conditioner by yourself. Replace the fan motor or the indoor board if disabled. Hello th error code of air conditioner GREE KFR-35GW “–” error code. Sensor Malfunction. Solution: Wait three minutes for the protection delay to expire. If indoor unit detects the condensate overflow switch warning for 8-secsuccessively, the system will entercondensate overflow protection.The unit will shut off and will not recover automatically. If outdoor unit detects the condensercoil temperature sensor open circuit or shortcircuit for 5-secsuccessively,condensercoil temperature sensor malfunction will be reported.The unitcan automatically resume operation after the malfunction disappears. If the PCB is to be replaced, please take off the old for the new PCB. Midea Outdoor Air Conditioner Error Display = E0 Error Code Definition = EEPROM error Controller is damaged. A/C Status: During cooling and drying operation, the compressor will stop while indoor fan will operate; During heating operating, the complete unit will stop operation. Compressor Overload Protection. If the malfunction occurs 6 times within one hour, the unitcannot be recovered automatically. If the protection occurs over 6 times, the unit will not recover automatically. In some cases, problems can be solved easily without the help from the Customer Service department just by checking the following. Indoor Ambient Temperature Sensor at ReturnAir Inlet Malfunction. Malfunction Name: Low pressure protection of compressor, Malfunction Name: High pressure protection of system, A/C Status: During cooling and drying operation, except indoor fan operates, all loads stop operation. The LPP terminal on the main board is not connected well, with the high pressure switch on the complete unit. What is it? In thiscase, the unit can automatically resume operation after stopping. Measure the voltage of position L and N on wiring board (XT), if the voltage is higher than 150VAC, turn on the unit after the supply voltage is increased to the normal range. I have a 1200 square foot gree mini split showing a U7 code coming up on the indoor unit. It shuts the unit down and then it will work later. Malfunction Name: Limit/decrease frequency due to antifreezing, Possible Causes: Poor air-return in indoor unit or fan speed is too low. Diciotto pagine di spiegazioni e suggerimenti, per conoscere fino in fondo il tuo nuovo climatizzatore Daitsu, Il Climafacile. Compressor High Discharge Temperature Protection. If the wired Tether Controller detects open circuit or shortcircuit of its temperature sensor for 5-secsuccessively,wired controller temperature sensor malfunction will be reported. E4: High discharge temperature protection of compressor, E8: High temperature resistant protection, EU: Limit/ decrease frequency due to high temperature of module, Fo: Gathering refrigerant-Nominal cooling mode, F1: Indoor ambient temperature sensor is open/short circuited, F2: Indoor evaporator temperature sensor is open/short circuited, F3: Outdoor ambient temperature sensor is open/short circuited, F4: Outdoor condenser temperature sensor is open/short circuited, F5: Outdoor discharge temperature sensor is open/short circuited, F6: Limit/ decrease frequency due to overload, F8: Decrease frequency due to overcurrent, F9: Decrease frequency due to high air discharge, FH: Limit/ decrease frequency due to antifreezing, P0: Compressor Min frequence in test state, P1: Compressor rated frequence in test state, P2: Compressor maximum frequence in test state, P3: Compressor intermediate frequence in test state, P5: Overcurrent protection of phase current for compressor, P7: Malfunction of module temperature sensor circuit, H0: Decrease frequency due to high temperature resistant during heating operation, H6: Internal motor (fan motor) do not operate, LP: Indoor unit and outdoor unit doesn’t match, U1: Malfunction of phase current detection circuit for compressor, U3: Malfunction of voltage dropping for DC bus-bar, U5: Malfunction of complete units current detection, U9: Zerocrossing malfunction of outdoor unit, Models: GWH09KF-A3DNB1A / GWH12KF-A3DNB1A/ GWH09KF-D3DNB1C/ GWH12KF-D3DNB1C/ GWH18KG-D3DNB1C/ GWH24KG-D3DNB1A, Gree Portable Air Conditioner Error Codes. If indoor unit detects the evaporator temperature sensor is open circuit or shortcircuit for 5-secsuccessively, evaporator temperature sensor malfunction will be reported.The unitcan automatically resume operation after the malfunction disappears. Check if the unit is within hightemperature, high-humidity environment. ��x���T�cH�mnY����[a�#z�ܰf�̶����^<4ZJĶ\w�\P���������֣��$��4����wc�m���]D����,i�:_8��~�v���e��r����;Lj��+��=l.=#�6��8�wS�E��W��ӛ��}��$��$�F� S�=)��JJ�b. If outside temperature or humidity is too high, turn off unit. Wired Controller Temp. Switch unit off and then switch it on to eliminate this malfunction. Malfunction Name: Malfunction of complete unit’s current detection. Fan blade rotates roughly due to improper installation. Cause: While it is normal for the system to generate condensate water in coolingmode, it is designed to drain this water via a condensate drain system to a safe location. This category only includes cookies that ensures basic functionalities and security features of the website. The batteries might be low. Problem: Malfunction of evaporator temperature sensor. If the malfunction occurs 3 times, the unit will not recover automatically. Thermistor/Bad Connection, or Outdoor Ambient Sensor Failure, Outdoor Coil Temp. During heating operation, the complete unit stops, Possible Causes: Refer to the corresponding malfunction analysis, Malfunction Name: High temperature resistant protection, A/C Status: During cooling operation: compressor will stop while indoor fan will operate. Hello i have dc inverter 1.5 ton when power on ofter 30 mint trip Ac indoor and out door is power off. Your email address will not be published. Solution: If water is leaking into the room, it may indicate one of the following. Thermistor/Bad Connection, or Indoor Air Sensor Failure, Indoor Coil Temp. During cooling and drying operation, compressor stops and indoor fan operates; During heating operation, the complete unit stops operation. Turn unit off, pull out power plug. Check if the evaporator and condenser are blocked. Kindly give me an help. Necessary cookies are absolutely essential for the website to function properly. La ditta declina ogni responsabilità per i risultati di una progettazione o di una installazione basata sulle spiegazioni e le specifiche tecniche Your email address will not be published. Malfunction Name: Outdoor ambient temperature sensor is open/ short-circuited. value and the compressor is stopped for 3-min. A thin fog or vapor coming out of the indoor unit when system is running. But opting out of some of these cookies may affect your browsing experience. If the indoor unit does not receive signal from indoor fan motor for 30-secsuccessively when the fan motor is operating, indoor fan motor malfunction will be reported. Vuoi scoprire le ultime tecnologie, eventi, apps e servizi del mondo Samsung? Cause: It is normal for the system to emit a slight fog or water vapor when cooling extremely humid warm air. Cosa significa l'errore E4 16 sul display del condizionatore? Solution: The condensation or moisture will disappear as the system cools and dehumidifies the room space. Decodifica dei codici di errore di tipo E. E0 indica una violazione della funzione di scarico della condensa. Compressor Discharge Temperature Sensor Malfunction. Comment:*document.getElementById("comment").setAttribute( "id", "a3b7bb2707d9360a2fdd996e0c170264" );document.getElementById("bb3ce808f8").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment.